3.6 MW Caterpillar 3616 Gas Generator Set

Engine: G3616, 1000 rpm, 6.3 KV, 50 HZ, Generator: SR4, Year 1999, Hours 40,000, control panels, batteries, gas valves, silencers. Complete package maintained and fully serviced under contract since new. History and maintenance records available on site at the time of inspection.

Twitt
Read More

13440 KW Siemens Back Pressure Steam Turbine

13440 KW Siemens Back Pressure Steam Turbine
Turbine 6500 rpm, Gear 1500 rpm, 50 HZ, 6.3 KV, Year: 1973,
Max inlet steam flow: 120 ton/h, Pressure: admission steam 43bar
Backpressure: 4bar (3,5 – 5 bar), Temp: 435°C, Min. time for starting:10 min, Min. load-time: 27 min, Included 40,000 Euros of spares. Turbine has been well maintained and is in very good condition

Twitt
Read More

WANTED WARTSILA DIESEL ENGINES

We need one Wartsila engine (Industrial or Marine) of each model 12V25, 16V25 & 18V200 for generator set applications. We require low running engines with documentation.

Twitt
Read More

5.7 MW Caterpillar 3612 Gas Generator Plant

5.7 MW Caterpillar 3612 Gas Power Plant
Two (2) 2850 KW Caterpillar 3612 Natural Gas Generator Sets,1000 rpm, 50 HZ, Year 1993, 10.5 KV, Only 16,000 hrs since Major overhaul. Complete plant with panels, exhaust silencers, Heat exchanger, gas lines, compressor, tank, cables, tools, spare parts, Plant is in excellent condition and has been very well maintained since new. All service records are available and can be viewed at time of inspection.

Twitt
Read More

26000 KVA Duetz Diesel Containerized Power Plant

26000 KVA Duetz Diesel Containerized Power Plant
Thirteen (13) 2000 KVA Duetz TBD 620V16 Diesel Generator Sets, Leroy Somer alternators, 400 volt, 50 HZ, Year 2001, 450 to 9000 hrs. Each generator packaged is housed in a silenced acoustic container that is CSC plated and holds a current certificate for shipping worldwide.
NEW batteries, battery chargers, switchgear, fuel tanks and a 20 ft container
of NEW spare parts. Complete plant that has been inspected and load bank tested.
Complete Plant easily installed with quick set up time for immediate power.

Twitt
Read More

16 MW Stal Laval Back Pressure Steam Turbine

16 MW Stal Laval Back Pressure Steam Turbine
Working pressure: 36 bar, max pressure: 42 bar Extraction: 11,8 bara,
backpressure: 4,7 bara. Steamflow: 158 T/h, Extraction flow: 30T/h, Temp.450 C,
6300 volt, 50 HZ, Year: 1955, The plant has only 25,000 hrs since the turbine and generator had a complete overhaul throughout in 2001 at a cost of 2.2 million euros.
All magnetism equipment and vibration equipment new in 1996. Plant is in excellent condition. We can offer the plant dismantled and shipped to port.

Twitt